Item #

The Taylor K-1000 Residential OTO 3-Way Test Kit for Total Chlorine, Bromine, and pH takes the guess work out of water testing for maintaining the best quality pool water.

Kit Includes:

  • .75 oz bottles of R-0060 Orthotolidine 
  • R-0014 pH Indicator Solution.
  • Testing Block.
  • Carrying Case.
  • Instructions.
      Know someone who might like this? - Please, feel free to " Tell A Friend "


      Item # Description/Size Qty Break Price Quantity
      K-1000
      3-Way Test Kit for Total Chlorine, Bromine, pH (OTO)
      1 $12.88
      K-1000-12
      3-Way Test Kit for Total Chlorine, Bromine, pH (OTO), 12-pack
      1 $140.53
      K-1000F
      3-Way Test Kit for Total Chlorine, Bromine, pH (OTO), French
      1 $12.88
      K-1000S
      3-Way Test Kit for Total Chlorine, Bromine, pH (OTO), Spanish
      1 $12.88
      K-1000S-12
      3-Way Test Kit for Total Chlorine, Bromine, pH (OTO), 12-pack, Spanish
      1 $140.53
      AnalyteSystemMethod/ChemistryStandard/Equivalance or DescriptionComparatorCell
      Bromine, TotalsureCHECK comparatorOT1, 2, 4, 6, 10 ppm bromine (Br₂)9781NA
      Chlorine, TotalsureCHECK comparatorOT.5, 1, 2, 3, 5 ppm chlorine (Cl₂)9781NA
      pHsureCHECK comparatorPhenol red6.8, 7.2, 7.5, 7.8, 8.29781NA
      Test ParameterDescription
      pHIron > 10 ppm may cause negative interference.
      pHSanitizer levels > approx. 10 ppm may cause a blue-purple color resulting in false high readings. Wait for sanitizer level to decrease to normal levels and retest to assure an accurate reading.

      REAGENT SHELF LIFE

      All reagents have a shelf life, whether they are liquids, powders, crystals, tablets, or test-strip pads. If kept dry, powders and crystals are very stable; acids are also long lived. Date of manufacture is not the controlling factor when it comes to shelf life—storage conditions are more important. As with all perishables, reagents are sensitive to environmental influences and will last longer under controlled conditions.

      To this end, we recommend:

      • Storing reagents at a consistent temperature in the range if 36°–85°F (2°–29°C); extreme temperature fluctuation, say from a refrigerator to a hot car trunk, causes reagents to deteriorate.
      • Keeping them out of prolonged direct sunlight. (Note: their brown plastic bottles help protect very light-sensitive reagents.)
      • Segregating reagents from containers of treatment chemicals.
      • Replacing caps immediately and tightening them carefully so that exposure to air and humidity is limited.
      • Avoiding switching bottle caps, placing bottle caps on soiled surfaces, repouring reagents into contaminated containers, or touching test strip pads.

      Taylor formulates its reagents to remain effective for at least one year, with only very few exceptions (molybdenum indicator in liquid form is one; after four months old it should be tested against a standard periodically). As a general precaution, replace all reagents more than one year old, or at the beginning of a new testing season.

        Click to view and download additional resources: